Menu
Home
About the Forest
Research
Data
Publications
Outreach
About Us
Home
About the Forest
Research
Data
Publications
Outreach
About Us
MS005
Attribute:
SOILTEMP_METHOD
code
description
SOI020
Soil temperature is sampled by type T thermocouple soldered from thermocouple wire at 10 cm depth with a Campbell Scientific data logger; mean temperature is output every 6 hours
SOI021
Soil temperature is sampled by type T thermocouple soldered from thermocouple wire at 20 cm depth with a Campbell Scientific data logger; mean temperature is output every 6 hours
SOI022
Soil temperature is sampled by type T thermocouple soldered from thermocouple wire at 30 cm depth with a Campbell Scientific data logger; mean temperature is output every 6 hours
SOI023
Soil temperature is sampled by a Campbell Scientific model 107 thermistor at 10 cm depth; mean temperature is output every 6 hours
SOI024
Soil temperature is sampled by a Campbell Scientific model 107 thermistor at 20 cm depth; mean temperature is output every 6 hours
SOI025
Soil temperature is sampled by a Campbell Scientific model 107 thermistor at 30 cm depth; mean temperature is output every 6 hours
SOI026
Soil temperature is sampled by type T thermocouple soldered from thermocouple wire at 10 cm depth with a Campbell Scientific data logger; mean temperature is output every 5 minutes
SOI027
Soil temperature is sampled by type T thermocouple soldered from thermocouple wire at 20 cm depth with a Campbell Scientific data logger; mean temperature is output every 5 minutes
SOI028
Soil temperature is sampled by type T thermocouple soldered from thermocouple wire at 30 cm depth with a Campbell Scientific data logger; mean temperature is output every 5 minutes
SOI029
Soil temperature is sampled by a Campbell Scientific model 107 thermistor at 10 cm depth; mean temperature is output every 5 minutes
SOI030
Soil temperature is sampled by a Campbell Scientific model 107 thermistor at 20 cm depth; mean temperature is output every 5 minutes
SOI031
Soil temperature is sampled by a Campbell Scientific model 107 thermistor at 30 cm depth; mean temperature is output every 5 minutes
SOI115
Mean daily soil temperature is determined from digitizing circular Partlow charts. Temperature is recorded by a Dual Recording Thermometer Model RFHTT with mercury bulb at 20 cm depth
SOI116
Mean daily (sunrise to sunrise) soil temperature is determined from digitizing circular Partlow charts. Temperature is recorded by a Dual Recording Thermometer Model RFHTT with mercury bulb at 20 cm depth
SOI117
Mean daily, max and min soil temperature is calculated by the Campbell Scientific datalogger based on 15 second samples. Instrument is type T thermocouple soldered from thermocouple wire at 10 cm depth (Daily output only)
SOI118
Mean daily, max and min soil temperature is calculated by the Campbell Scientific datalogger based on 15 second samples. Instrument is type T thermocouple soldered from thermocouple wire at 20 cm depth (Daily output only)
SOI119
Mean daily, max and min soil temperature is calculated by the Campbell Scientific datalogger based on 15 second samples. Instrument is type T thermocouple soldered from thermocouple wire at 30 cm depth (Daily output only)
SOI120
Mean daily, max and min soil temperature is calculated by the Campbell Scientific datalogger based on 15 second samples. Instrument is type T thermocouple soldered from thermocouple wire at 10 cm depth (See Method SOI020)
SOI121
Mean daily, max and min soil temperature is calculated by the Campbell Scientific datalogger based on 15 second samples. Instrument is type T thermocouple soldered from thermocouple wire at 20 cm depth (See Method SOI021)
SOI122
Mean daily, max and min soil temperature is calculated by the Campbell Scientific datalogger based on 15 second samples. Instrument is type T thermocouple soldered from thermocouple wire at 30 cm depth (See Method SOI022)
SOI123
Mean daily, max and min soil temperature is calculated by the Campbell Scientific datalogger based on 15 second samples. Instrument is Campbell Scientific model 107 thermistor at 10 cm depth (See Method SOI023)
SOI124
Mean daily, max and min soil temperature is calculated by the Campbell Scientific datalogger based on 15 second samples. Instrument is Campbell Scientific model 107 thermistor at 20 cm depth (See Method SOI024)
SOI125
Mean daily, max and min soil temperature is calculated by the Campbell Scientific datalogger based on 15 second samples. Instrument is Campbell Scientific model 107 thermistor at 30 cm depth (See Method SOI025)
SOI126
Mean daily soil temperature is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. Type T thermocouple wire at 10 cm depth (See Method SOI026)
SOI127
Mean daily soil temperature is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. Type T thermocouple wire at 20 cm depth (See Method SOI027)
SOI128
Mean daily soil temperature is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. Type T thermocouple wire at 30 cm depth (See Method SOI028)
SOI129
Mean daily soil temperature is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. Campbell Scientific model 107 thermistor at 10 cm depth (See Method SOI029)
SOI130
Mean daily soil temperature is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. Campbell Scientific model 107 thermistor at 20 cm depth (See Method SOI030)
SOI131
Mean daily soil temperature is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. Campbell Scientific model 107 thermistor at 30 cm depth (See Method SOI031)