Menu
Home
About the Forest
Research
Data
Publications
Outreach
About Us
Home
About the Forest
Research
Data
Publications
Outreach
About Us
TP108
Attributes in entity
17
:
Disturbance Assessment: Cover (U-I1)
Details
1. DATACODE
Definition:
FSBD Database Code
Domain:
enum
2. ENTITY
Definition:
Entity Number
Units:
number
Domain:
range (minimum = 17. maximum = 17.)
3. YEAR
Definition:
Year in which plot was sampled
Units:
year (yyyy)
Domain:
range (minimum = 1998. maximum = 1999.)
6. DISTRICT
Definition:
National Forest System Code indicating location of the study block by National Forest and Ranger District
Domain:
place
7. BLOCK
Definition:
Sample block number
Domain:
enum
8. TRT
Definition:
Treatment unit
Domain:
enum
9. PLOT
Definition:
Sample plot code designating block, plot, and a grid system location (e.g. 1A7: 1 = TRT, A = Row, 7 = Column)
Domain:
place
10. TRANS
Definition:
Letter Code designating Transect (A,B,C,D)
Domain:
enum
11. COVTYPE
Definition:
Type of Disturbance Cover
Domain:
enum
12. LC
Definition:
The number of lines of a single record within a species, growth form class or cover type
Units:
number
Domain:
range (minimum = 1. maximum = 3.)
13. CSTART1
Definition:
The beginning meter mark intersected by the first vertical projection of a cover type's surface
Units:
meters
Domain:
range (minimum = 0.00 maximum = 5.98)
14. CEND1
Definition:
The ending meter mark intersected by the first vertical projection of a cover type's surface
Units:
meters
Domain:
range (minimum = 0.02 maximum = 6.00)
15. CSTART2
Definition:
The beginning meter mark intersected by the 2nd projection of a cover type's surface
Units:
meters
Domain:
range (minimum = 0.19 maximum = 5.98)
16. CEND2
Definition:
The ending meter mark intersected by the 2nd projection of a cover type's surface
Units:
meters
Domain:
range (minimum = 0.32 maximum = 6.00)
17. CSTART3
Definition:
The beginning meter mark intersected by the 3rd projection of a cover type's surface
Units:
meters
Domain:
range (minimum = 0.40 maximum = 5.98)
18. CEND3
Definition:
The ending meter mark intersected by the 3rd projection of a cover type's surface
Units:
meters
Domain:
range (minimum = 0.53 maximum = 6.00)
19. CSTART4
Definition:
The beginning meter mark intersected by the 4th projection of a cover type's surface
Units:
meters
Domain:
range (minimum = 0.58 maximum = 5.97)
20. CEND4
Definition:
The ending meter mark intersected by the 4th projection of a cover type's surface
Units:
meters
Domain:
range (minimum = 1.28 maximum = 6.00)
21. CSTART5
Definition:
The beginning meter mark intersected by the 5th projection of a cover type's surface
Units:
meters
Domain:
range (minimum = 1.46 maximum = 5.98)
22. CEND5
Definition:
The ending meter mark intersected by the 5th projection of a cover type's surface
Units:
meters
Domain:
range (minimum = 1.80 maximum = 6.00)
23. PTYPE
Definition:
Code indicating uncut (0) or cut (1) Plot
Domain:
enum
24. PERSONNEL
Definition:
Name(s) of crew member(s) who sampled plots
Domain:
freetext
25. SAMPLEDATE
Definition:
Date on which plot was sampled
Units:
date as date type
Domain:
range (minimum = Jun 4 1998 maximum = Sep 22 1999)