Menu

CF012

Attributes in entity 1: Specific conductance (electrical conductivity) and stream water temperature (5 minute resolution)

     Details
1. DBCODE
Definition: FSDB database code
Domain: enum
2. ENTITY
Definition: Entity number
Units: number
Domain: range (minimum = 1.  maximum = 1.)
3. SITECODE
Definition: Sitecode for the gauging station
Domain: place
4. EC_METHOD
Definition: General method and instrumentation used to collect specific conductivity and water temperature
Domain: enum
5. QC_LEVEL
Definition: Quality control flag indicates level of quality checking performed including an indication of "provisional" data
Domain: enum
6. PROBE_CODE
Definition: Probe number code indicates the measurement type, site, and sensor number, e.g., CNDGS101
Domain: enum
7. DATE_TIME
Definition: Date and time in Pacific Standard Time (PST) of sensor reading
Units: date as datetime type
Domain: range (minimum = Oct 26 2011 2:15PM  maximum = Oct 1 2019 12:00AM)
8. EC_INST
Definition: Instantaneous specific conductance (electrical conductivity) measurement
Units: micro siemens per centimeter
Domain: range (minimum = 1.0  maximum = 694.0)
9. EC_INST_FLAG
Definition: Instantaneous specific conductance measurement flag
Domain: enum
10. WATERTEMP_INST
Definition: Instantaneous water temperature measurement
Units: degrees Celsius
Domain: range (minimum = -0.1  maximum = 25.0)
11. WATERTEMP_INST_FLAG
Definition: Instantaneous water temperature measurement flag
Domain: enum
12. EVENT_CODE
Definition: Type of comment that exists independently for any event, disruption in protocol, or unusual conditions that occur at the given date or time and may have an effect on the data values
Domain: enum