Attribute:
DEWPT_METHOD
code
description
DEW001
Dewpoint temperature is measured with a heated lithium-chloride dewpoint sensor at 100 cm height and recorded continuously on a separate 30-day Rustrak strip chart; the mean is output every 60 minutes
DEW002
Dewpoint temperature is measured indirectly by a heated Interface Instrument lithium-chloride hygrometer with a linear thermistor at 150 cm height; the mean is output every 60 minutes
DEW003
Dewpoint temperature is measured indirectly by a heated Interface Instrument lithium-chloride hygrometer with a linear thermistor at 100 cm height; the mean is output every 60 minutes
DEW004
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP35C probe housed in a cotton region shelter at 150 cm height; the mean is output every 60 minutes
DEW005
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP35C probe housed in a locally designed PVC radiation shield at 150 cm height; the mean is output every 60 minutes
DEW006
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP35C probe housed in a locally designed PVC radiation shield at 450 cm height; the mean is output every 60 minutes
DEW007
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP35C probe housed in a locally designed PVC radiation shield at 480 cm height; the mean is output every 60 minutes
DEW008
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a locally designed PVC radiation shield at 150 cm height; the mean is output every 60 minutes
DEW009
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a locally designed PVC radiation shield at 450 cm height; the mean is output every 60 minutes
DEW010
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP35C probe housed in a R.M. Young Gill radiation shield at 450 cm height; the mean is output every 60 minutes
DEW011
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 150 cm height; the mean is output every 60 minutes
DEW012
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 450 cm height; the mean is output every 60 minutes
DEW014
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 150 cm height; the mean is output every 15 minutes
DEW015
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 450 cm height; the mean is output every 15 minutes
DEW016
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 150 cm height; the mean is output every 5 minutes
DEW017
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 450 cm height; the mean is output every 5 minutes
DEW018
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 150 cm height; mean, min
DEW019
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 450 cm height; mean, min
DEW020
Dew point temperature is sampled by a Campbell Scientific model HC2S3-L probe housed in a R.M. Young Gill radiation shield at 150 cm height; mean, min and max dew point temperature is output every 5 minutes
DEW104
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP35C; cotton region shelter; 150 cm (DEW004)
DEW105
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP35C; PVC radiation shield; 150 cm (DEW005)
DEW106
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP35C; PVC radiation shield; 450 cm (DEW006)
DEW107
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP35C; PVC radiation shield; 480 cm (DEW007)
DEW108
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP45C; PVC radiation shield; 150 cm (DEW008)
DEW109
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP45C; PVC radiation shield; 450 cm (DEW009)
DEW110
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP35C; RM Young Gill shield; 450 cm (DEW010)
DEW111
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP45C; RM Young Gill shield; 150 cm (DEW011)
DEW112
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CS Model HMP45C; RM Young Gill shield; 450 cm (DEW012)
DEW114
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CS Model HMP45C; RM Young Gill shield; 150 cm (DEW014)
DEW115
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CS Model HMP45C; RM Young Gill shield; 450 cm (DEW015)
DEW118
Mean daily dew point temperature is post-calculated from all 5 minute mean, max and min values for the day. Max-min values are based on instantaneous values per 5 minute intervals. CS Model HMP45C; RM Young Gill shield; 150 cm height (See method DEW018)
DEW119
Mean daily dew point temperature is post-calculated from all 5 minute mean, max and min values for the day. Max-min values are based on instantaneous values per 5 minute intervals. CS Model HMP45C; RM Young Gill shield; 450 cm height (See method DEW019)
DEW120
Mean daily dew point temperature is post-calculated from all 5 minute mean, max and min values for the day. Max-min values are based on instantaneous values per 5 minute intervals. CS Model HC2S3-L; RM Young Gill shield; 150 cm height (See method DEW020)
DEW201
Mean daily dew point temperature is calculated from hourly chart readings. Min-max values are based on hourly mean values. Heated lithium-chloride dewpoint sensor at 100 cm height records continuously on 30-day Rustrak strip chart; mean output 60 minutes
DEW202
Mean daily dew point temperature is calculated from hourly means. Min-max values are based on hourly mean values. Heated Interface Instrument lithium-chloride hygrometer with a linear thermistor at 150 cm height; mean is output every 60 minutes
DEW203
Mean daily dew point temperature is calculated from hourly means. Min-max values are based on hourly mean values. Heated Interface Instrument lithium-chloride hygrometer with a linear thermistor at 100 cm height; mean is output every 60 minutes
DEW211
Mean daily dew point temperature is post-calculated from all hourly mean values for the day. Max-min values are based on hourly mean intervals and not instantaneous values. CS Model HMP45C; RM Young Gill shield; 150 cm height (See method DEW011)
DEW212
Mean daily dew point temperature is post-calculated from all hourly mean values for the day. Max-min values are based on hourly mean intervals and not instantaneous values. CS Model HMP45C; RM Young Gill shield; 450 cm height (See method DEW012)
DEW214
Mean daily dew point temperature is post-calculated from all15 minute mean values for the day. Max-min values are based on 15 minute mean intervals and not instantaneous values. CS Model HMP45C; RM Young Gill shield; 150 cm height (See method DEW014)
DEW215
Mean daily dew point temperature is post-calculated from all15 minute mean values for the day. Max-min values are based on 15 minute mean intervals and not instantaneous values. CS Model HMP45C; RM Young Gill shield; 450 cm height (See method DEW015)
DEW216
Mean daily dew point temperature is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. CS Model HMP45C; RM Young Gill shield; 150 cm height (See method DEW016)
DEW217
Mean daily dew point temperature is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. CS Model HMP45C; RM Young Gill shield; 450 cm height (See method DEW017)
DEW311
Mean daily dew point temperature is post-calculated from all hourly mean values for the day. Max-min values are calculated from 15 second readings of air temperature and relative humidity. CS Model HMP45C; RM Young Gill shield; 150 cm (DEW011)
DEW312
Mean daily dew point temperature is post-calculated from all hourly mean values for the day. Max-min values are calculated from 15 second readings of air temperature and relative humidity. CS Model HMP45C; RM Young Gill shield; 450 cm (DEW012)
DEW314
Mean daily dew point temperature is post-calculated from all 15 minute mean values for the day. Max-min values are calculated from 15 second readings of air temperature and relative humidity. CS Model HMP45C; RM Young Gill shield; 150 cm (method DEW014)
DEW315
Mean daily dew point temperature is post-calculated from all 15 minute mean values for the day. Max-min values are calculated from 15 second readings of air temperature and relative humidity. CS Model HMP45C; RM Young Gill shield; 450 cm (method DEW015)