MS001
Attribute:
DEWPT_METHOD
code
description
DEW001
Dewpoint temperature is measured with a heated lithium-chloride dewpoint sensor at 100 cm height and recorded continuously on a separate 30-day Rustrak strip chart; the mean is output every 60 minutes
DEW002
Dewpoint temperature is measured indirectly by a heated Interface Instrument lithium-chloride hygrometer with a linear thermistor at 150 cm height; the mean is output every 60 minutes
DEW003
Dewpoint temperature is measured indirectly by a heated Interface Instrument lithium-chloride hygrometer with a linear thermistor at 100 cm height; the mean is output every 60 minutes
DEW004
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP35C probe housed in a cotton region shelter at 150 cm height; the mean is output every 60 minutes
DEW005
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP35C probe housed in a locally designed PVC radiation shield at 150 cm height; the mean is output every 60 minutes
DEW006
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP35C probe housed in a locally designed PVC radiation shield at 450 cm height; the mean is output every 60 minutes
DEW007
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP35C probe housed in a locally designed PVC radiation shield at 480 cm height; the mean is output every 60 minutes
DEW008
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a locally designed PVC radiation shield at 150 cm height; the mean is output every 60 minutes
DEW009
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a locally designed PVC radiation shield at 450 cm height; the mean is output every 60 minutes
DEW010
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP35C probe housed in a R.M. Young Gill radiation shield at 450 cm height; the mean is output every 60 minutes
DEW011
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 150 cm height; the mean is output every 60 minutes
DEW012
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 450 cm height; the mean is output every 60 minutes
DEW014
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 150 cm height; the mean is output every 15 minutes
DEW015
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 450 cm height; the mean is output every 15 minutes
DEW016
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 150 cm height; the mean is output every 5 minutes
DEW017
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 450 cm height; the mean is output every 5 minutes
DEW018
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 150 cm height; mean, min
DEW019
Dew point temperature is calculated from air temperature and relative humidity sampled every 15 seconds by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 450 cm height; mean, min
DEW020
Dew point temperature is sampled by a Campbell Scientific model HC2S3-L probe housed in a R.M. Young Gill radiation shield at 150 cm height; mean, min and max dew point temperature is output every 5 minutes
DEW021
Dew point temperature is sampled by a Campbell Scientific (CS) CR1000 data logger and CS HC2S3-L probe housed in a R.M. Young Gill radiation shield at 150 cm height; sampling rate 10 seconds; 5-minute output is the minimum, mean, and maximum of 30 samples.
DEW104
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP35C; cotton region shelter; 150 cm (DEW004)
DEW105
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP35C; PVC radiation shield; 150 cm (DEW005)
DEW106
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP35C; PVC radiation shield; 450 cm (DEW006)
DEW107
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP35C; PVC radiation shield; 480 cm (DEW007)
DEW108
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP45C; PVC radiation shield; 150 cm (DEW008)
DEW109
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP45C; PVC radiation shield; 450 cm (DEW009)
DEW110
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP35C; RM Young Gill shield; 450 cm (DEW010)
DEW111
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CSModel HMP45C; RM Young Gill shield; 150 cm (DEW011)
DEW112
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CS Model HMP45C; RM Young Gill shield; 450 cm (DEW012)
DEW114
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CS Model HMP45C; RM Young Gill shield; 150 cm (DEW014)
DEW115
Mean daily dew point temperature is calculated by the Campbell Scientific datalogger from air temperature and relative humid sampled every 15 seconds. Max-min values are based on 15 second readings. CS Model HMP45C; RM Young Gill shield; 450 cm (DEW015)
DEW118
Mean daily dew point temperature is post-calculated from all 5 minute mean, max and min values for the day. Max-min values are based on instantaneous values per 5 minute intervals. CS Model HMP45C; RM Young Gill shield; 150 cm height (See method DEW018)
DEW119
Mean daily dew point temperature is post-calculated from all 5 minute mean, max and min values for the day. Max-min values are based on instantaneous values per 5 minute intervals. CS Model HMP45C; RM Young Gill shield; 450 cm height (See method DEW019)
DEW120
Mean daily dew point temperature is post-calculated from all 5 minute mean, max and min values for the day. Max-min values are based on instantaneous values per 5 minute intervals. CS Model HC2S3-L; RM Young Gill shield; 150 cm height (See method DEW020)
DEW121
Dew point temperature is sampled by a Campbell Scientific (CS) CR1000 data logger and CS HC2S3-L probe housed in a R.M. Young Gill radiation shield at 150 cm height; sampling rate 10 seconds; 5-minute output is the minimum, mean, and maximum of 30 samples. Daily mean minimum, mean, and maximum are post-calculated from 5-minute output.
DEW201
Mean daily dew point temperature is calculated from hourly chart readings. Min-max values are based on hourly mean values. Heated lithium-chloride dewpoint sensor at 100 cm height records continuously on 30-day Rustrak strip chart; mean output 60 minutes
DEW202
Mean daily dew point temperature is calculated from hourly means. Min-max values are based on hourly mean values. Heated Interface Instrument lithium-chloride hygrometer with a linear thermistor at 150 cm height; mean is output every 60 minutes
DEW203
Mean daily dew point temperature is calculated from hourly means. Min-max values are based on hourly mean values. Heated Interface Instrument lithium-chloride hygrometer with a linear thermistor at 100 cm height; mean is output every 60 minutes
DEW211
Mean daily dew point temperature is post-calculated from all hourly mean values for the day. Max-min values are based on hourly mean intervals and not instantaneous values. CS Model HMP45C; RM Young Gill shield; 150 cm height (See method DEW011)
DEW212
Mean daily dew point temperature is post-calculated from all hourly mean values for the day. Max-min values are based on hourly mean intervals and not instantaneous values. CS Model HMP45C; RM Young Gill shield; 450 cm height (See method DEW012)
DEW214
Mean daily dew point temperature is post-calculated from all15 minute mean values for the day. Max-min values are based on 15 minute mean intervals and not instantaneous values. CS Model HMP45C; RM Young Gill shield; 150 cm height (See method DEW014)
DEW215
Mean daily dew point temperature is post-calculated from all15 minute mean values for the day. Max-min values are based on 15 minute mean intervals and not instantaneous values. CS Model HMP45C; RM Young Gill shield; 450 cm height (See method DEW015)
DEW216
Mean daily dew point temperature is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. CS Model HMP45C; RM Young Gill shield; 150 cm height (See method DEW016)
DEW217
Mean daily dew point temperature is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. CS Model HMP45C; RM Young Gill shield; 450 cm height (See method DEW017)
DEW311
Mean daily dew point temperature is post-calculated from all hourly mean values for the day. Max-min values are calculated from 15 second readings of air temperature and relative humidity. CS Model HMP45C; RM Young Gill shield; 150 cm (DEW011)
DEW312
Mean daily dew point temperature is post-calculated from all hourly mean values for the day. Max-min values are calculated from 15 second readings of air temperature and relative humidity. CS Model HMP45C; RM Young Gill shield; 450 cm (DEW012)
DEW314
Mean daily dew point temperature is post-calculated from all 15 minute mean values for the day. Max-min values are calculated from 15 second readings of air temperature and relative humidity. CS Model HMP45C; RM Young Gill shield; 150 cm (method DEW014)
DEW315
Mean daily dew point temperature is post-calculated from all 15 minute mean values for the day. Max-min values are calculated from 15 second readings of air temperature and relative humidity. CS Model HMP45C; RM Young Gill shield; 450 cm (method DEW015)