Menu
Home
About the Forest
Research
Data
Publications
Outreach
About Us
Home
About the Forest
Research
Data
Publications
Outreach
About Us
MS001
Attribute:
RELHUM_METHOD
code
description
REL004
Relative humidity is sampled by a Campbell Scientific model HMP35C probe housed in a cotton region shelter at 150 cm height; mean relative humidity is output every 60 minutes
REL005
Relative humidity is sampled by a Campbell Scientific model HMP35C probe housed in a locally designed PVC radiation shield at 150 cm height; mean relative humidity is output every 60 minutes
REL006
Relative humidity is sampled by a Campbell Scientific model HMP35C probe housed in a locally designed PVC radiation shield at 450 cm height; mean relative humidity is output every 60 minutes
REL007
Relative humidity is sampled by a Campbell Scientific model HMP45C probe housed in a locally designed PVC radiation shield at 150 cm height; mean relative humidity is output every 60 minutes
REL008
Relative humidity is sampled by a Campbell Scientific model HMP45C probe housed in a locally designed PVC radiation shield at 450 cm height; mean relative humidity is output every 60 minutes
REL009
Relative humidity is sampled by a Campbell Scientific model HMP45C probe housed in a locally designed PVC radiation shield at 450 cm height; program failure in output of relative humidty values
REL010
Relative humidity is sampled by a Campbell Scientific model HMP35C probe housed in a R.M. Young Gill radiation shield at 450 cm height; mean relative humidity is output every 60 minutes
REL011
Relative humidity is sampled by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 150 cm height; mean relative humidity is output every 60 minutes
REL012
Relative humidity is sampled by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 450 cm height; mean relative humidity is output every 60 minutes
REL013
Relative humidity is sampled by a Campbell Scientific model HMP35C probe housed in a locally designed PVC radiation shield at 480 cm height; mean relative humidity is output every 60 minutes
REL014
Relative humidity is sampled by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 150 cm height; mean relative humidity is output every 15 minutes
REL015
Relative humidity is sampled by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 450 cm height; mean relative humidity is output every 15 minutes
REL016
Relative humidity is sampled by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 150 cm height; mean relative humidity is output every 5 minutes
REL017
Relative humidity is sampled by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 450 cm height; mean relative humidity is output every 5 minutes
REL020
Relative humidity is sampled by a Campbell Scientific model HC2S3-L probe housed in a R.M. Young Gill radiation shield at 150 cm height; mean relative humidity is output every 5 minutes
REL021
Relative humidity is sampled by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 450 cm height; mean relative humidity is output every 10 minutes
REL022
Relative humidity is sampled by a Campbell Scientific model HMP45C probe housed in a R.M. Young Gill radiation shield at 150 cm height; mean relative humidity is output every 10 minutes
REL023
Relative humidity is sampled by a Campbell Scientific (CS) CR1000 data logger and CS HC2S3-L probe housed in a R.M. Young Gill radiation shield at 150 cm height; sampling rate 10 seconds; 5-minute output is the minimum, mean, and maximum of 30 samples.
REL101
Daily minimum and maximum relative humidity is recorded on a Cole Parmer hygrothermograph chart at 130 cm height in cotton region shelter; daily chart readings are adjusted weekly using a sling psychrometer
REL102
Daily minimum and maximum relative humidity is recorded on a Belfort hygrothermograph chart at 130 cm height in cotton region shelter; daily chart readings are adjusted weekly using a sling psychrometer
REL103
Mean daily relative humidity is calculated by the Campbell Scientific datalogger and output on a sunrise to sunrise basis. Max-min values are based on instantaneous 15 second readings. HMP35C; PVC radiation shield; 450 cm height
REL104
Mean daily relative humidity is calculated by the Campbell Scientific datalogger based on 15 second samples. Max-min values are based on instantaneous 15 second readings. CS Model HMP35C; cotton region shelter; 150 cm height (See method REL004)
REL105
Mean daily relative humidity is calculated by the Campbell Scientific datalogger based on 15 second samples. Max-min values are based on instantaneous 15 second readings. Model HMP35C; PVC radiation shield; 150 cm height (See method REL005)
REL106
Mean daily relative humidity is calculated by the Campbell Scientific datalogger based on 15 second samples. Max-min values are based on instantaneous 15 second readings. Model HMP35C; PVC radiation shield; 450 cm height (See method REL006)
REL107
Mean daily relative humidity is calculated by the Campbell Scientific datalogger based on 15 second samples. Max-min values are based on instantaneous 15 second readings. Model HMP45C; PVC radiation shield; 150 cm height (See method REL007)
REL108
Mean daily relative humidity is calculated by the Campbell Scientific datalogger based on 15 second samples. Max-min values are based on instantaneous 15 second readings. Model HMP45C; PVC radiation shield; 450 cm height (See method REL008)
REL109
Mean daily relative humidity is not output; program failure of the Campbell Scientific datalogger. Model HMP45C; PVC radiation shield; 450 cm height (See method REL009)
REL110
Mean daily relative humidity is calculated by the Campbell Scientific datalogger based on 15 second samples. Max-min values are based on instantaneous 15 second readings. Model HMP35C; R.M. Young Gill radiation shield; 450 cm height (See method REL010)
REL111
Mean daily relative humidity is calculated by the Campbell Scientific datalogger based on 15 second samples. Max-min values are based on instantaneous 15 second readings. Model HMP45C; R.M. Young Gill radiation shield; 150 cm height (See method REL011)
REL112
Mean daily relative humidity is calculated by the Campbell Scientific datalogger based on 15 second samples. Max-min values are based on instantaneous 15 second readings. Model HMP45C; R.M. Young Gill radiation shield; 450 cm height (See methodREL012)
REL113
Mean daily relative humidity is calculated by the Campbell Scientific datalogger based on 15 second samples. Max-min values are based on instantaneous 15 second readings. Model HMP35C; PVC radiation shield; 480 cm height (See method REL013)
REL211
Mean daily relative humidity is post-calculated from all hourly mean values for the day. Max-min values are based on hourly mean intervals and not instantaneous values. Model HMP45C; R.M. Young Gill radiation shield; 150 cm height (See method REL011)
REL212
Mean daily relative humidity is post-calculated from all hourly mean values for the day. Max-min values are based on hourly mean intervals and not instantaneous values. Model HMP45C; R.M. Young Gill radiation shield; 450 cm height (See method REL012)
REL214
Mean daily relative humidity is post-calculated from all 15 minute mean values for the day. Max-min values are based on 15 minute mean intervals and not instantaneous values. Model HMP45C; R.M. Young Gill radiation shield; 150 cm height (See meth REL014)
REL215
Mean daily relative humidity is post-calculated from all 15 minute mean values for the day. Max-min values are based on 15 minute mean intervals and not instantaneous values. Model HMP45C; R.M. Young Gill radiation shield; 450 cm height (See meth REL015)
REL216
Mean daily relative humidity is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. Model HMP45C; R.M. Young Gill radiation shield; 150 cm height (See method REL016)
REL217
Mean daily relative humidity is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. Model HMP45C; R.M. Young Gill radiation shield; 450 cm height (See method REL017)
REL220
Mean daily relative humidity is post-calculated from all 5 minute mean values for the day. Max-min values are based on 5 minute mean intervals and not instantaneous values. Model HC2S3-L; R.M. Young Gill radiation shield; 150 cm ht (See method REL020)
REL221
Mean daily relative humidity is post-calculated from all 10 minute mean values for the day. Max-min values are based on 10 minute mean intervals and not instantaneous values. Model HMP45C; R.M. Young Gill radiation shield; 450 cm ht (See method REL021)
REL222
Mean daily relative humidity is post-calculated from all 10 minute mean values for the day. Max-min values are based on 10 minute mean intervals and not instantaneous values. Model HMP45C; R.M. Young Gill radiation shield; 150 cm ht (See method REL022)
REL223
Relative humidity is sampled by a Campbell Scientific (CS) CR1000 data logger and CS HC2S3-L probe housed in a R.M. Young Gill radiation shield at 150 cm height; sampling rate 10 seconds; 5-minute output is the minimum, mean, and maximum of 30 samples. Daily mean, mean minimum and mean maximum are post-calculated from 5-minute mean data.
REL311
Mean daily relative humidity is post-calculated from all hourly mean values for the day. Max-min values are based on instantaneous 15 second readings. Model HMP45C; R.M. Young Gill radiation shield; 150 cm height (See method REL011)
REL312
Mean daily relative humidity is post-calculated from all hourly mean values for the day. Max-min values are based on instantaneous 15 second readings. Model HMP45C; R.M. Young Gill radiation shield; 450 cm height (See method REL012)
REL314
Mean daily relative humidity is post-calculated from all 15 minute mean values for the day. Max-min values are based on instantaneous 15 second readings. Model HMP45C; R.M. Young Gill radiation shield; 150 cm height (See method REL014)
REL315
Mean daily relative humidity is post-calculated from all 15 minute mean values for the day. Max-min values are based on instantaneous 15 second readings. Model HMP45C; R.M. Young Gill radiation shield; 450 cm height (See method REL015)