Mean, minimum, and maximum air temperature over a 5-minute interval
Details
1. DBCODE
Definition:
FSDB Database Code (MS048)
Domain:
enum
2. ENTITY
Definition:
Entity number
Units:
number
Domain:
range (minimum = 3. maximum = 3.)
3. SITE
Definition:
Site where data collected
Domain:
place
4. DATE_TIME
Definition:
Date and time collected
Units:
date as datetime type
Domain:
range (minimum = Feb 10 2015 10:20PM maximum = Apr 27 2017 2:05AM)
5. ASPIRATED_MEAN
Definition:
Mean air temperature measurement for interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young Model 43502-L compact aspirated shield at 150 cm height
Units:
degrees Celsius
Domain:
range (minimum = -13.0 maximum = 226.0)
6. ASPIRATED_MEAN_FLAG
Definition:
Rows flagged for QA issues, including missing and out of range values
Domain:
enum
7. ASPIRATED_MAX
Definition:
Maximum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young Model 43502-L compact aspirated shield at 150 cm height
Units:
degrees Celsius
Domain:
range (minimum = -12.8 maximum = 156.7)
8. ASPIRATED_MAX_FLAG
Definition:
Rows flagged for QA issues, including missing and out of range values
Domain:
enum
9. ASPIRATED_MIN
Definition:
Minimum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young Model 43502-L compact aspirated shield at 150 cm height
Units:
degrees Celsius
Domain:
range (minimum = -13.2 maximum = 40.1)
10. ASPIRATED_MIN_FLAG
Definition:
Rows flagged for QA issues, including missing and out of range values
Domain:
enum
11. CRS_MEAN
Definition:
Mean air temperature measurement for interval sampled by a Campbell Scientific model 107 thermistor housed in a NovaLynx 380-605 large instrument (cotton region) shelter at 150 cm height
Units:
degrees Celsius
Domain:
range (minimum = -13.3 maximum = 41.7)
12. CRS_MEAN_FLAG
Definition:
Rows flagged for QA issues, including missing and out of range values
Domain:
enum
13. CRS_MAX
Definition:
Maximum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a NovaLynx 380-605 large instrument (cotton region) shelter at 150 cm height
Units:
degrees Celsius
Domain:
range (minimum = -13.3 maximum = 41.9)
14. CRS_MAX_FLAG
Definition:
Rows flagged for QA issues, including missing and out of range values
Domain:
enum
15. CRS_MIN
Definition:
Minimum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a NovaLynx 380-605 large instrument (cotton region) shelter at 150 cm height
Units:
degrees Celsius
Domain:
range (minimum = -94.2 maximum = 41.5)
16. CRS_MIN_FLAG
Definition:
Rows flagged for QA issues, including missing and out of range values
Domain:
enum
17. GILL_MEAN
Definition:
Mean air temperature measurement for interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young 41303-5A 6-plate radiation shield at 150 cm height
Units:
degrees Celsius
Domain:
range (minimum = -13.6 maximum = 74.2)
18. GILL_MEAN_FLAG
Definition:
Rows flagged for QA issues, including missing and out of range values
Domain:
enum
19. GILL_MAX
Definition:
Maximum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young 41303-5A 6-plate radiation shield at 150 cm height
Units:
degrees Celsius
Domain:
range (minimum = -13.5 maximum = 68.4)
20. GILL_MAX_FLAG
Definition:
Rows flagged for QA issues, including missing and out of range values
Domain:
enum
21. GILL_MIN
Definition:
Minimum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a R.M. Young 41303-5A 6-plate radiation shield at 150 cm height
Units:
degrees Celsius
Domain:
range (minimum = -38.0 maximum = 41.3)
22. GILL_MIN_FLAG
Definition:
Rows flagged for QA issues, including missing and out of range values
Domain:
enum
23. HJA_MEAN
Definition:
Mean air temperature measurement for interval sampled by a Campbell Scientific model 107 thermistor housed in a locally designed radiation shield at 150 cm height (8-inch long, 3.5 inch diameter, schedule 40 PVC pipe split in half lengthwise
Units:
degrees Celsius
Domain:
range (minimum = -14.0 maximum = 43.1)
24. HJA_MEAN_FLAG
Definition:
Rows flagged for QA issues, including missing and out of range values
Domain:
enum
25. HJA_MAX
Definition:
Maximum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a locally designed radiation shield at 150 cm height (8-inch long, 3.5 inch diameter, schedule 40 PVC pipe split in half lengthwis
Units:
degrees Celsius
Domain:
range (minimum = -13.9 maximum = 43.5)
26. HJA_MAX_FLAG
Definition:
Rows flagged for QA issues, including missing and out of range values
Domain:
enum
27. HJA_MIN
Definition:
Minimum air temperature measurement for a 5-minute interval sampled by a Campbell Scientific model 107 thermistor housed in a locally designed radiation shield at 150 cm height (8-inch long, 3.5 inch diameter, schedule 40 PVC pipe split in half lengthwis
Units:
degrees Celsius
Domain:
range (minimum = -109.0 maximum = 42.8)
28. HJA_MIN_FLAG
Definition:
Rows flagged for QA issues, including missing and out of range values
Domain: